7 days a week
Full fault code coverage
All work covered
10+ years experience
The fault code information below is provided for reference only. Stairlifts are heavy mechanical devices, and some faults (particularly safety gear, over-speed governor and accelerometer faults) need a qualified engineer. If you're not sure what's wrong, call us on 0800 567 7033 before attempting anything.
Which Acorn curved stairlift do you have?
The Acorn 80 and Acorn 180 are the same curved stairlift. The only difference is the main PCB fitted, which changes the fault code system.
Acorn 180 (later PCB)
Uses letter-number codes:
A1 · C1 · E1 · F5 · F7
If your display shows codes like these, look at the Acorn 180 section below.
Acorn 80 (earlier PCB)
Uses single-character codes:
5. · U. · d. · E. · 0–9
If your display shows codes like these, look at the Acorn 80 section below.
🔧 Looking for something else?
This page covers fault codes and diagnosis for the Acorn 80 and 180. For general Acorn repairs, Brooks stairlifts, jammed rollers, or if your stairlift just needs a service, see our Acorn stairlift repair hub page →.
Acorn 180 fault codes (later PCB)
Every Acorn 180 code, what it means, and what to do.
A-Series codes
Batteries not recharging. Beeps for about a minute, then goes into hibernation.
What to do: Check the mains supply is on. Park on the charge points. Let the batteries recharge. The display shows C1 while charging and C4 once full.
Moving up.
What to do: Nothing. This is normal.
Moving down.
What to do: Nothing. This is normal.
Moving up via the remote control.
Moving down via the remote control.
Waiting for the hinge. The stairlift is waiting for the hinge to operate.
C-Series codes
Charging mode. The stairlift is on its charge point.
What to do: Nothing. This is normal.
Batteries fully charged.
What to do: Nothing. This is normal.
E-Series codes (safety edges)
Down-side foot safety edge has been activated.
What to do: Check for obstructions on the down-side foot plate.
Up-side foot safety edge has been activated.
What to do: Check for obstructions on the up-side foot plate.
Under-foot-plate safety edge has been activated.
What to do: Check underneath the foot plate.
Down-side safety edge has been activated.
What to do: Check the down-side safety edge.
Up-side safety edge has been activated.
What to do: Check the up-side safety edge.
The seat has been swivelled away from its operating position.
What to do: Return the seat to the locked position.
F-Series codes (critical)
Battery flat, audible alarm sounding.
What to do: Press the arm switch or remote once to stop the alarm. Bring the stairlift to the nearest charging point.
⚠️ Safety gear is on. Safety-critical fault.
What to do: Call us straight away. Don't use the stairlift until an engineer has checked it. Read our full guide to the OSG fault →
Number codes (0–4)
Batteries not charged.
What to do: Drive the stairlift to the nearest charging point.
Accelerometer sensor fault.
What to do: Call us.
Seat not level.
What to do: Level it with the hand winder. If it keeps happening, call us.
Lost datum or programming fault.
What to do: Call us.
Searching mode.
What to do: Call us.
Acorn 80 fault codes (earlier PCB)
The earlier main PCB uses single-character codes. If your display shows any of these, you'll find them below.
Normal operation
Standby. Ready to use.
Moving up the rail.
Moving down the rail.
At correct stopped position.
Batteries fast charging (small light on).
Batteries trickle charging (small light flashing).
Programming modes
No datum is set. Programming mode is required.
Datum search is on.
Programming mode is on.
Programming terminal limits (charge point positions).
Fault conditions
These codes only appear when a call has been made.
No battery power.
What to do: Check the mains supply and charge points.
The seat is swivelled out of its operating position.
What to do: Return the seat to the locked position.
The hinged rail isn't down in its operating position.
What to do: Check the hinge is fully down.
Seat or footrest not in operating position.
What to do: Check the seat and footrest.
Pressure Sensitive Edge (PSE) has been activated.
What to do: Check for obstructions on the safety edges.
Conflicting call signal between the armrest control and the remote.
What to do: Release both controls and try again.
Not enough charge to complete a full journey.
What to do: Drive to the nearest charge point.
Installation error (flashing display), or motor brake failure.
What to do: Call us.
Feed fault. No power on the main control circuit.
What to do: Check the supply, then call us.
The stairlift has overrun the normal parking position.
What to do: Call us.
Over-speed governor isn't rotating.
What to do: Call us.
Levelling over-travel limit switch protection.
What to do: Call us.
PCB power frame failure.
What to do: Call us. This may need a PCB replacement.
Main drive motor polarity is wrong.
What to do: Call us.
Levelling motor polarity is wrong.
What to do: Call us.
Encoder failure (main drive or levelling drive).
What to do: Call us.
Accelerometer failure.
What to do: Call us straight away.
Stairlift is out of level. Electronic shutdown.
What to do: Call us.
Stairlift isn't being charged.
What to do: Check the mains supply and charge point.
Main drive over speed.
What to do: Call us.
Levelling over speed.
What to do: Call us.
Acorn curved stairlift troubleshooting tips
A few safe checks you can try before giving us a call.
🔧 Override instruction (if code 6 shows)
- Switch off the lift at the on/off switch.
- Put the call in using the rocker switch in the required direction.
- Switch the lift on while holding the call in on the rocker switch.
- The lift will now drive.
Note: This is for temporary recovery only. If the fault comes back, call us.
📏 Levelling the seat
The seat is levelled by a potentiometer and should be set correctly from the factory. If it goes out of level:
- Turn the seat shaft manually with the hand winder.
- If it keeps tilting randomly, it may be an encoder fault. Call us.
Warning: We'd recommend this is done by a qualified engineer.
🔌 F1 relay reset (emergency only)
F1 is a relay fault on the main PCB. It's caused by hot-switch relay signals.
Emergency reset (temporary): With the power off, gently tap the relay with a screwdriver to release it from being jammed.
⚠️ Important: This is for emergency recovery only. Call us straight away to have it properly repaired.
⚠️ Over-speed governor (OSG)
If you remove the power bogie covers to access the OSG, check the regulator and trigger arm are in the correct position.
⚠️ Warning: If the OSG doesn't look right, do NOT try to move the carriage. Call us immediately. Read our OSG guide →
These should always be handled by a qualified engineer: F7 (safety gear), F1 (relay fault), OSG issues, accelerometer faults, and any damage to safety edges or rollers. Call 0800 567 7033.
Common Acorn problems we fix
The jobs we're called out to most often.
- ✅ Stairlift beeping or flashing fault codes
- ✅ Not charging, batteries going flat
- ✅ Stuck mid-flight, or won't respond
- ✅ Seat tilting or not level
- ✅ Grinding noise on straight runs or bends
- ✅ Running much slower than usual
- ✅ Over-speed governor (OSG) has tripped
- ✅ Remote control not responding
🔈 Grinding noise means worn rollers
If your Acorn makes a grinding noise on straight runs or around a bend, that usually means the rollers are worn. Another sign is the stairlift suddenly running much slower. Worth getting it looked at quickly, before the rail and carriage suffer further damage. More on Acorn roller problems →
📞 Book a roller inspectionWhy choose us for Acorn repairs
We know Acorn curved stairlifts well, and we have the parts and experience to fix them properly.
🔧 Acorn specialists
Our engineers know Acorn curved stairlifts inside out, from small fault codes to full PCB replacement.
✅ Genuine and compatible parts
We use genuine Acorn parts and manufacturer-approved compatible components, so your stairlift performs safely and reliably.
⚡ Fast, guaranteed service
Same-day and next-day callouts available. Every job comes with a warranty, for peace of mind.
Acorn repairs in your area
Our engineers are based in strategic locations to provide national coverage.
Acorn curved stairlift repair FAQs
Quick answers to the questions we hear most.
How do I know if I have an Acorn 80 or Acorn 180?
The Acorn 80 and 180 are the same curved stairlift. The difference is the main PCB fitted. The earlier PCB (Acorn 80) shows single-character codes like 5, U, d, E and 0-9. The later PCB (Acorn 180) shows letter-number codes like A1, C1, E1, F5 and F7.
What does code A1 mean on an Acorn 180?
Code A1 means the batteries aren't recharging. Check the mains supply is on and the stairlift is parked on its charge points. Give the batteries time to recharge before using it again.
What does code F7 mean on an Acorn 180?
Code F7 means the safety gear is on. That's a safety-critical fault. Call us straight away on 0800 567 7033. Don't use the stairlift until an engineer has checked it.
What does a blank display mean on an Acorn 80?
A blank display usually means no battery power. Check the mains supply is on and the stairlift is parked on its charge points. If it stays blank after a full charge, call 0800 567 7033.
Why is my Acorn curved stairlift making a grinding noise?
A grinding noise on the straight run or around a bend normally means the rollers are worn. It's worth getting it looked at quickly to avoid further damage.
Can I reset an Acorn fault code myself?
Some codes clear if you switch the stairlift off and on again, or follow the override procedure. But safety-critical faults (F7, OSG, accelerometer) should always be looked at by a qualified engineer. Call 0800 567 7033 for advice.
Acorn stairlift not working?
Call us for fast, guaranteed Acorn repairs, 7 days a week.